FREE PICK UP on all Testing Kits.

Menu

Offices

8 Item(s)

per page

Grid  List 

Set Descending Direction
  1. legionella testing kit for showers

    Legionella test on Showers

    £44.50

    Test Kit for Laboratory analysis of water sample from Showers for legionella bacteria

    Learn More
  2. Potable Water Quality Test on CWS Tanks

    Potable Water Quality Test on CWS Tanks

    £25.00

    Cold Water Storage Tank Potable Water Quality Test Kit. A Laboratory analysis of stored cold water in a CWS tank to check it is fit to drink

    Learn More
  3. Showerhead Plus Gel

    Showerhead Plus Gel

    £49.50

    Showerhead Plus Gel

    Learn More
  4. Showerhead Plus

    Showerhead Plus

    £79.92

    Showerhead plus descales and disinfects at the same time. Proven to kill legionella bacteria.

    Learn More
  5. Water Quality Test on Drinking Water Unit

    Water Quality Test on Drinking Water Unit

    £25.00

    Drinking Water Unit - Water Quality Test Kit (post-flush). A Laboratory analysis of a Drinking Water Unit to check it is fit to drink 

    Learn More
  6. Vending Machine Water Quality Test

    Vending Machine Water Quality Test

    £25.00

    Vending Machine Water Quality Test Kit (pre-flush). A Laboratory analysis of a vending machine sample to check it is fit to drink

    Learn More
  7. Potable Water Quality test kit

    Potable Water Quality Test Kit

    £25.00

    Potable Water Quality test kit

    Learn More
  8. Legionella Test on Water Heaters & Calorifiers

    Legionella Test on Water Heaters & Calorifiers

    £44.50

    Test Kit for Laboratory analysis of water sample from Water Heaters & Calorifiers for legionella bacteria 

    Learn More

8 Item(s)

per page

Grid  List 

Set Descending Direction

LEGIONELLA TESTING – OFFICES

Legionella test kits for Offices

Danger Areas

Most modern offices have simple water systems which represent a fairly low legionella risk. Older workplaces were designed for different times, for example 30 years ago Telephone Exchanges employed hundreds of staff. These workplaces required huge quantities of stored water for the canteens and toilets. Modern technology means these same buildings employ less than 10 people but the pipework to the disused canteen and redundant toilets still remain.

Many companies install showers in their executives’ offices, maybe also in the basement for the cyclists and joggers. If these become rarely used, they represent a risk not just to the showers but to all other areas as the bacteria migrate.

Sometimes poor maintenance means hot water temperatures reduce due to scale build-up in boilers/calorifiers or maybe a failed return pump goes undetected. These situations allow water in the distribution pipework to cool below the recommended temperatures so that any legionella are either not killed, or worse still, provide an ideal environment for growth.

Independent legionella testing will establish if a problem exists, if so it can be investigated and procedures put in place to prevent reoccurrence.

LAW

  • Management of Health & Safety at Work Regulations 1999
  • Control of Substances Hazardous to Health Regulations 1999
  • Health & Safety at Work Act 1974

RELEVANT DOCUMENTS

HSG274 Legionnaires’ disease: Technical guidance:-

  • Part 2: The control of legionella bacteria in hot & cold water systems


HSE- Legionnaires’ disease A guide for employers